Basic Info.
Type
Self-Starting Diesel Generator
Installation Method
Portable
Conditions of Use
Land Use
Landuse Type of Unit
Low Noise
Product Description
Specification of 8-15kw diesel generator With epa approval:
Model of gen-set 8gf(8kw) 10gf(10kw)
Model of engine yd385d yd385d
Type vertical, water-cooling, four-stocke, vertical vertical, water-cooling, four-stocke, vertical
Number of cylinders 3 3
Bore(mm) 85 85
Stroke (mm) 90 90
Compression ratio 22: 1 22: 1
Total displacement(l) 1. 532 1. 532
Firing order 1-3-2 1-3-2
Rated power(12h, kw) 9. 07 11. 33
Rated speed(r/min) 1800 1800
Max. Torque(n. M) ≥84 ≥84
Min. Specific fuel consumption at full load(g/kw. H) ≤267. 9 ≤267. 9
Specific lube oilconsumption(g/kw. H) 2. 72 2. 72
Advance angle of supply fuel/speed(before tdc)()/r/min 10± 1/3000(with advance device) 18± 1/2800 16± 1/2600 15± 1/2400 10± 1/3000(with advance device) 18± 1/2800 16± 1/2600 15± 1/2400
Injection pressure 13. 2± 0. 5 13. 2± 0. 5
Direction of crankshaft rotation(facing to flywheel) counterclockwise counterclockwise
Cooling method forced water cooling forced water cooling
Starting method electric electric
Model of alternator st-8 or tfw-10 st-10 or tfw-10
Rated power 8kw 10kw
Rated voltage 120/240v 120/240v
Rated current 33. 3 41. 6
Rated frequency 60hz 60hz
Rated speed(r/min) 1800r/min 1800r/min
Power factor 1 or 0. 8 1 or 0. 8
Phase connection 1 or 3 1 or 3
Winding connection 3 or 4 -wire 3 or 4 -wire
Exciation brush or brushless brush or brushless
Insulation class b or f(for tfw-12kw brushless) b or f(for tfw-12kw brushless)
Voltage regulation method avr avr
Steady-state-voltage ip23 ip23
Control panel v-meter, a-meter, frequency meter, circuit breaker, transfer v-meter, a-meter, frequency meter, circuit breaker, transfer
Switch, light, etc. Switch, light, etc.
Net mass(kg) 420 420
Overall dimensions(l× W× H)(m) 1. 23*0. 70*0. 98 1. 23*0. 70*0. 98
Specification of 8-15kw diesel generator:
With epa approval
Model of gen-set 12kw 15kw
Model of engine yd385d yd485d
Type vertical, water-cooling, four-stocke, vertical vertical, water-cooling, four-stocke, vertical
Number of cylinders 3 4
Bore(mm) 85 85
Stroke (mm) 90 90
Compression ratio 22: 1 22: 1
Total displacement(l) 1. 532 2. 043
Firing order 1-3-2 1-3-4-2
Rated power(12h, kw) 13. 6 21
Rated speed(r/min) 1800 1800
Max. Torque(n. M) ≥84 ≥112
Min. Specific fuel consumption at full load(g/kw. H) ≤267. 9 ≤267. 9
Specific lube oilconsumption(g/kw. H) 2. 72 2. 72
Advance angle of supply fuel/speed(before tdc)()/r/min 10± 1/3000(with advance device) 18± 1/2800 16± 1/2600 15± 1/2400 10± 1/3000(with advance device) 18± 1/2800 16± 1/2600 15± 1/2400
Injection pressure 13. 2± 0. 5 13. 2± 0. 5
Direction of crankshaft rotation(facing to flywheel) counterclockwise counterclockwise
Cooling method forced water cooling forced water cooling
Starting method electric electric
Model of alternator st-12 or tfw-12 st-15 or tfw-15
Rated power 12kw 15kw
Rated voltage 120/240v 120/240v
Rated current 50 62. 5a
Rated frequency 60hz 60hz
Rated speed(r/min) 1800r/min 1800r/min
Power factor 1 or 0. 8 1 or 0. 8
Phase connection 1 or 3 1 or 3
Winding connection 3 or 4 -wire 3 or 4 -wire
Exciation brush or brushless brush or brushless
Insulation class b or f(for tfw-12kw brushless) b or f(for tfw-15kw brushless)
Voltage regulation method avr avr
Steady-state-voltage ip23 ip23
Control panel v-meter, a-meter, frequency meter, circuit breaker, transfer v-meter, a-meter, frequency meter, circuit breaker, transfer
Switch, light, etc. Switch, light, etc.
Net mass(kg) 420 450
Overall dimensions(l× W× H)(m) 1. 36*0. 70*0. 98 1. 50*0. 70*0. 98